Download Print deze pagina

Parkside PDM 300 C3 Handleiding En Veiligheidsvoorschriften pagina 43

Advertenties

For measurements of lower resistances (200 Ω range), the resistance of
the device's own measurement cables can distort the reading. In order to
avoid this, note down the reading for the measurement with the
measurement probes short-circuited, and subtract this from the actual
measurement reading.
7.7 Continuity testing
CAUTION! Make sure that all circuit components, circuits and parts to
be measured are disconnected and discharged. Otherwise the multimeter
could get damaged.
• Connect the black measurement cable to the COM connection [4] and the
red measurement cable to the
• Set the range selector switch [3] to the
• Connect the measurement probes [6] to the object to be measured.
• If the resistance is under about 30 Ω, the buzzer sounds and the measured
reading is shown on the display [1].
7.8 Diode test
CAUTION! Make sure that all circuit components, circuits and parts to
be measured are disconnected and discharged. Otherwise the multimeter
could get damaged.
• Connect the black measurement cable to the COM connection [4] and the
red measurement cable to the
• Set the range selector switch [3] to the
• Connect the red measurement probe [6] to the anode of the diode to be
tested and the black measurement probe [6] to the cathode.
OUT INPUT connection [5].
position.
OUT INPUT connection [5].
position.
PARKSIDE PDM 300 C3
English - 41

Advertenties

loading

Deze handleiding is ook geschikt voor:

365005 2204