Fault
LEDs on the
battery
1 LED emits
red light.
3 LEDs flash
red.
3 LEDs light up
red.
4 LEDs fla‐
shing red.
The blower swit‐
3 LEDs light up
ches off while in
red.
operation.
The blower ope‐
rating time is too
short.
18 Specifications
18.1
STIHL BGA 100 Blower
– Approved batteries:
• STIHL AR
• STIHL AP together with "AP belt bag with
connecting cable"
– Air speed with nozzle mounted: 63 m/s
– Weight: 2.5 kg
For battery life see www.stihl.com/battery-life.
26
Cause
The battery is too
warm or too cold.
There is a fault in the
blower.
The blower is too
warm.
There is a fault in the
battery.
There is a break in the
electrical connection
between the blower
and the battery.
The blower or the bat‐
tery is damp.
The blower is too
warm.
There is an electrical
fault.
The battery is not fully
charged.
The battery service
life has been excee‐
ded.
18.2
K-value for sound pressure level is 2 dB(A). K-
value for sound power level is 2 dB(A). K-value
for vibration level is 2 m/s².
STIHL recommends that you wear hearing pro‐
tection.
– Sound pressure level L
to EN 50636‑2‑100: 80 dB(A)
– Sound power level L
EN 50636-2-100: 90 dB(A)
Remedy
► Pull the connecting cable plug out of the
socket.
► Allow the battery to cool down or warm
up.
► Pull connecting cable plug out of the
socket and plug it in again.
► Turn on blower.
► If 3 LEDs continue to flash red: Do not
use the blower and contact your STIHL
dealer for assistance.
► Pull the connecting cable plug out of the
socket.
► Allow the blower to cool down.
► Pull connecting cable plug out of the
socket and plug it in again.
► Turn on blower.
► If 4 LEDs continue to flash red: Do not
use the battery; contact a STIHL authori‐
zed dealer.
► Pull connecting cable plug out of the
socket and plug it in again.
► If blower still does not start when swit‐
ched on: Clean contacts of connecting
cable as described in the User Manual
for the STIHL AR battery or the "AP belt
bag with connecting cable".
► Allow blower or battery to dry.
► Pull the connecting cable plug out of the
socket.
► Allow the blower to cool down.
► Pull connecting cable plug out of the
socket and plug it in again.
► If blower continues to cut out during ope‐
ration: Clean contacts of connecting
cable as described in the User Manual
for the STIHL AR battery or the "AP belt
bag with connecting cable".
► Turn on blower.
► Fully charge battery as described in the
User Manual for the STIHL AL 101, 301,
301-4, 500 chargers.
► Replace battery.
Noise and Vibration Data
pA
measured according to
wA
18 Specifications
measured according
0458-711-9621-C