27 / 88 | EN
snaps into the black plastic holders.
9
LockNode is fixed.
6
9. Attach the supplied thumb-turn cover with the glued-in
contact foil (pay attention to the markings).
9
Cylinder beeps four times.
7
10. Turn the thumb-turn cover clockwise until it stops.
11. Pull the recessed grip outwards until it is flush with the
thumb-turn cover.
12. Place the battery/installation key on the electronic side
thumb-turn so that the two noses engage in the open-
ings of the locking disc (if necessary, turn the thumb-turn
until the noses engage).
13. Hold the thumb-turn firmly and turn the battery/installa-
tion key about 30° counterclockwise.
The locking disc will click.
9
LockNode is mounted.
9
If the cylinder does not beep, check the battery condition.
Information for SmartIntego users
SimonsVoss recommends the following procedure:
1.
Remove the existing LockNode.
3. Installing a LockNode MP