Download Inhoudsopgave Inhoud Print deze pagina

Atag ES9111EM Gebruiksaanwijzing pagina 61

Inhoudsopgave

Advertenties

INSTALLATION
Fitting
Fig.2
• the extractor fan from the packaging and remove the 2 screws A
from the inner frame. You can now separate the inner frame from
the top part.
• Hold the drilling template against the ceiling. Ensure that the arrow
is on the control panel side of the extractor fan.
• Drill the connection holes with a diameter of 8 mm for fitting the
inner frame B in the ceiling.
• Place suitable plugs in the drilled holes.
• Do not place a screw at position X. Do place screws in the
remaining three holes. Do not tighten these screws completely.
• Slide the inner frame B over the three screws.
• Make a small turning movement so that the three screws fall into
the grooves.
• Fasten the fourth screw X and tighten all screws.
• Fasten the bottom part of the inner frame C to the top part B.
• Adjust the desired height.
GB 13

Advertenties

Inhoudsopgave
loading

Inhoudsopgave