Control Panel

Set the Operating Temperature

1. Hold the SET button for 3 seconds. The display
will flash.
2. Press the
or
required temperature.
3. Press the SET button to store the temperature.
Manual Defrost
The appliance will automatically run a defrost
cycle every 4 hours.
To manually defrost the appliance: Press and
hold the defrost button "
to begin a manual defrost. The defrost light
illuminates.
The defrost cycle will end automatically.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
The unit is not switched on
working
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Appliance is noisy or
Appliance is not level
works intermittently
The appliance is touching a
neighbouring object
Cooler cabinet is not
Temperature set incorrectly
cold enough
External environment may
require colder temperature
The door is opened too often Only open when necessary
Door seal is worn
Water box overflowing
Ambient conditions
Condensation
Condensation may occur when the humidity is high and water particles in the air
contact with cold surfaces. This is normal, just wipe away with a dry cloth
4
GE769_ML_A5_v3_20241108.indb 4
GE769_ML_A5_v3_20241108.indb 4
Cleaning, Care &
Maintenance
Condensation and ice will form with frequent
and prolonged opening of the doors.
buttons to display the
Operating outside of the recommend
temperature range and placing next to a
heat source will also increase the amount
of ice and internal/external condensation.
If external condensation occurs wipe the
surface down with a cloth.
Excessive ice will result in longer running
times that will increase energy consumption
" for 2 seconds
and increase the deterioration of
components.
If the gasket or seal is damaged or deformed,
energy consumption will increase. To restore
efficiency, replace gasket.
Probable Cause
Check the unit is plugged in correctly and switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Check installation position and change if necessary
Check installation position and change if necessary
Check temperature and reset if necessary
Check temperature and reset if necessary
Consult a qualified Technician
Turn Power Off and remove plug from socket.
Remove back panel and scoop the water out
Switch off and disconnect from the power
supply before cleaning.
Clean the interior of the appliance as often as
possible.
Do not use abrasive cleaning agents. These
can leave harmful residues.
Always wipe dry after cleaning.
If left unused for any length of time, store the
appliance with the door ajar.
Solution