ERROR AND TROUBLE-
Error message
Possible cause
on the screen
204
Miscalculation
208
Miscalculation of
excessive current flow.
220
Discarged batteries /
battery
252
Hight temperature
253
Low temperature
255
Poor signal or
measurement time due to
low reflection surface
256
Strong signal due to high
reflexion surface
261
Measurement target too
far away/too close
500
Hardware damage
198

SHOOTING MESSAGES

Problem solve
Repeat the measurement process.
Contact the dealer.
Change the batteries.
The meter will be cool down, for example, in
a cool room. The outer temperature must be
between 0 °C to + 40 °C
The rangefinder will be heated, for example
storage in a warm room. The outer
temperature must be between 0 °C to + 40 °C
Increase the degree of reflexion, for example
with a white paper in the measurement point.
A dark colour paper decrese the reflexion
degree
Measurements can only be carried out within
a range of 20 m (max.) to 15 cm (min.).
Try repeatedly to turn on and o the
rangefinder. If the error message persists,
there is a damage. Please contact your dealer.