the button for interval mode (10). The LED to the right of the interval
button (11) lights up if interval mode has been switched on. Julia will
now diffuse fragrance into the room for 10 minutes. The appliance will
then switch off for 20 minutes. This mode means it is possible to diffuse
the fragrances in pleasantly small doses into the air. The advantage:
You don't become accustomed to the fragrances and can therefore still
smell them all the time.
9. If you are disturbed by the brightness of the LEDs or by the illuminated
mist (in the bedroom for example), you can reduce the brightness of all
LEDs by pressing the dimmer button (12). You can choose between three
different modes:
• Normal mode (switched on as standard)
• Dimmed mode (press once)
• Light-off mode (press twice)
You can return to normal mode by re-pressing the dimmer button (12).
10. The moving mist output can be activated by pressing the swing mode
button (13) on the back of the device. The mist now swings at an angle
of approx. 160° to ensure optimum distribution of fragrance in the room.
11. Always switch the device off before you top up the water or fragrances
(8). If the device is operated at the second output level, you have to press
twice and once at the first output level for the device to be switched
off (the LEDs are no longer lit up). Then pull out the network adapter
(1). Remove the upper part (3) and the lid (4) and top the water up to the
maximum mark (6).
Note: If you would like to change the fragrance, empty Julia completely and
clean the water container (5) with a damp cloth. Fill Julia once again and
pour the drops into the device following the instructions.
Cleaning
Before maintenance and after every use, switch the device off and pull the
network adapter (1) out of the socket. Before you clean Julia, the network
adapter must be unplugged.
Careful: Never immerse the device in water (danger of short circuit).
• To clean the outside, rub with a damp cloth and then dry thoroughly.
• Internal cleaning: You can clean the ultrasonic membrane (7) with a con-
ventional household descaler. If there are lime deposits, we recommend
that you use Stadler Form Cleaner & Descaler (www.stadlerform.com/
accessories). Alternatively, you can use a household descaling agent or
vinegar. Please do not try to scratch off deposits from the membrane with
a hard object. For stubborn deposits, we recommend that you descale
the device several times in a row. After the descaling rinse the water
container (5) and then dry thoroughly.
• No water may enter the air outlet opening (15). This will damage the ap-
pliance and will void any claim to the warranty.