LED Reading
E90
E94
Water temperature too low
E95
Water temperature too high
E96
E97
E99
Water temperature sensor broken • Contact Intex Service Center.
After 72 hours of continuous
heating operation, the pump will
END
hibernate automatically. The rapid
heating and water fi ltration
Freeze Protection: the spa heater is programed to automatically heat the water if the water temperature
falls below 4°C (39°F). While the spa should be stored during the winter months, the system will protect the
internal components in the event of occasional freezing temperatures. The spa must be plugged in and the
GFCI/RCD reset. The system will engage the fi lter pump along with the heater and will operate both until the
water reaches 10°C (50°F).
If extended freezing weather is expected, please disassemble the spa and store it during winter according to
the storage instructions.
Once the self-heating program is triggered, it cannot be switched off on the control panel until the water
temperature has reached at least 5°C (41°F), unless it is unplugged.
S AVE THESE INSTRUCTIONS

LED CODE CHART

CAUSE
No water fl ow
System Error
Dry-fi re Protection
functions are disabled.
(347IO) SPA ENGLISH 7.5" X 10.3" PANTONE 295U 04/16/2022
SOLUTION
• Turn off and unplug the control unit.
• Ensure the outlet cover grid is clean and free
from obstructions.
• Clean or replace the cartridge, see
Maintenance and Storage section.
• Ensure the in/outlet connections on the spa tub
and fi lter pump are not blocked.
• Keep the spa water properly sanitized to
ensure a clean and unclogged fi lter cartridge.
• If problem persists, contact Intex Service
Center.
• If the ambient temperature is below 0°C (32°F),
we recommend not to use the spa.
• Turn off and unplug the control unit, add some
warm water to raise the spa water temperature
above 1°C (34°F), then press the
heat up the water to the desired temperature.
• If problem persists, contact Intex Service
center.
• Turn off and unplug the control unit. When the
water has cooled down, plug the RCD and
restart all over again.
• Turn the heater off , then press the fi lter and
bubble buttons to lower the water temperature.
• If problem persists, contact Intex Service
Center.
• Turn off and unplug the control unit. Plug the
RCD and restart all over again.
• If problem persists, contact Intex Service
Center.
• Contact Intex Service Center.
• Press the
button to re-active the
fi lter pump.