Parameters table
Table of parameters for PJEZY*,PJEZC*,PJEZS*J*
Description
PS
Password
-C1
Probe 1 calibration
-C2
Probe 2 calibration
St
Control temperature
rd
Control differential
c0
Comp. and fan start delay after start-up
c2
Min. compressor off time
Type of defrost (0= heater; 1= hot gas;
d0
2= heater by time; 3= hot gas by time;
4= heater by time with temp. cont.)
dI
Interval between two defrosts
dt
End defrost temperature
dP
Max. or effective defrost duration
dd
Dripping time after defrost
Fan and alarm differential (≤0,AL and AH
A0
expressed as absolutes; >0,AL and AH
expressed relative to the set point)
Low temperature alarm threshold/deviation
AL
(when A0≤0,AL=-50:alarm disable, when
A0>0, AL=0:alarm disable)
High temperature alarm threshold/deviation
AH
(when A0≤0,AH=90:alarm disable, when
A0>0, AH=0:alarm disable)
Ad
Low and high temperature alarm delay
door related FAN or Light management
0= input not active
A4
1=door opening with FAN OFF
2= door opening with Light ON(FAN is not
available, Light output is activated)
F0
enable fan control
F1
Fans shutdown temperature
F2
fan off when compressor off
F3
fan states during defrost
Fd
post-dripping time
Start delay when FAN ON is required by the
F4
Regulation
F5
Fan Duty Cycle(with F2=2): ON time
F6
Fan Duty Cycle(with F2=2) : OFF time
r1
Minimum set point allowed to the user
r2
Maximum set point allowed to the user
Table of parameters for PJEZS*E*
Description
PS
Password
-C1
Probe 1 calibration
Control temperature
St
Control differential
rd
Comp. and fan start delay after start-up
c0
c2
Min. compressor off time
dI
Interval between two defrosts
Max. or effective defrost
dP
duration
Dripping time after defrost
dd
Fan and alarm differential (≤0,AL and AH
expressed as absolutes; >0,AL and AH
A0
expressed relative to the set point)
Low temperature alarm threshold/deviation
AL
(when A0≤0,AL=-50:alarm disable,when
A0>0, AL=0:alarm disable )
High temperature alarm threshold/deviation
AH
(when A0≤0,AH=90:alarm disable, when
A0>0, AH=0:alarm disable)
Ad
Low and high temperature alarm delay
Minimum set point allowed to the user
r1
Maximum set point allowed to the user
r2
*F: frequent parameters, without password
*C: configuration parameters, with password
CAREL INDUSTRIES HQs
Via dell'Industria, 11 - 35020 Brugine - Padova (Italy)
Tel. (+39) 0499716611 – Fax (+39) 0499716600 – http://www.carel.com – e-mail: carel@carel.com
Type
Min
Max Def. UOM
F
0
99
22
-
F
-20
20
0
°C
F
-20
20
0
°C
F
-50
90
4.0
°C
F
0
19
2.0
°C
C
0
99
0
Min
C
0
99
3
Min钟
C
0
4
0
-
C
0
24
8
Hour
C
-50
90
12
°C
C
1
99
30
Min钟
C
0
15
2
Min钟
C
-20
20
-2.0
°C
C
-50
90
-50
°C
C
-50
90
90
°C
C
0
99
0
Min钟
C
0
2
0
-
C
0
1
0
-
F
-50
99
5.0
°C
C
0
2
1
-
C
0
1
1
-
C
0
15
0
Min钟
C
1
99
3
Sec
C
1
99
5
Min钟
C
1
99
5
Min钟
C
-50
r2
-50
°C
C
r1
90
90
°C
Type
Min
Max Def. UOM
F
0
99
22
-
F
-20
20
0
°C
F
-50
90
4.0
°C
F
0
19
2.0
°C
C
0
99
0
Min
C
0
99
3
Min
C
0
24
8
Hour
C
1
99
30
Min
C
0
15
2
Min
C
-20
20
-2.0
°C
C
-50
90
-50
°C
C
-50
90
90
°C
C
0
99
0
Min
C
-50
r2
-50
°C
C
r1
90
90
°C
Fixed settings
Minimum compressor ON time is 1 minute;
If there is no defrost relay, the compressor will be shut down for defrost;
Freeze the display when defrost, it returns when the temperature reaches the set point;
Alarm is bypassed 1 hour after defrost;
Open door alarm will be activated after detecting the door opening 5 minutes.
Setting the set point (desired temperature)
press
for 1 s, the set value will start flashing after a few moments;
increase or decrease the value using
press
to confirm the new value.
Switching the device ON/OFF
press
for more than 3 s. The control and defrost algorithms are now disabled and the instru-
ment displays the message"OFF" alternating with the temperature read by the set probe.
Manual defrost (only for models C/Y)
press down
for DOWN more than 3 s (the defrost starts only the temperature conditions are
valid).
Show defrost probe temperture(only for models C/Y)
press
and
together.
Access and setting type F (frequent) and type C (configuration)
parameters
press
for 3 s (the display will show "PS");
to access the type F and C parameter menu, enter the password "22" using
to access the F parameter menu only, press
scroll inside the parameter menu using
To display/set the values of the parameter displayed, press
confirm the changes (returning to the parameter menu).
To save all the new values and exit the parameter menu, press
To exit the menu without saving the changed values (exit by timeout) do not press any button for
at least 60 s.
Display and functions
During normal operation, the controller displays the ambient temperature. In addition, the
display has LEDs that indicate the activation of the control functions (see Table 1), while the
3 buttons can be used to activate/deactivate some of the functions (see Table 2).
LEDs and associated functions
index
function
normal operation
ON
1
compressor
on
2
fan
on
3
defrost
on
4
aux
output on
5
digit
2 digit LED display with sign (-99 to 99) and decimal point
Table of functions activated by the buttons
normal operation
button
pressing the button alone
more than 3 s: toggle ON/OFF
more than 3 s: start/stop defrost
1 s: display/set the set point
More than 3 s: access
parameter setting menu(enter pass-
word '22')
or
;
/
(without entering the password);
/
.
, then
/
and finally to
for 3 s;
5
Start up
OFF
blink
off
request
on
off
request
on
off
request
on
output off
-
on
Table.1
start up
pressed together
-
pressed together
display defrost
For 1 s: display
probe temp.
firmware vers.
Pressed
code
together
start
parameter
reset pro-
-
cedure
+050004235 - rel. 1.1 - 10.06.2015
;
Table.2