+050004235 - rel. 1.1 - 10.06.2015
PJEZ (PJEZ****G/H/I/L/M/N/O/P*)
Dimensions (mm)
Panel mounting
Rear (with 2 quick-fit side brackets)
Electrical connections
PJEZS*
-10T50
1 2 3 4 5
6 7
or
L
N
PJEZ(C,Y)*
-10T50
1 2 3 4 5
6 7
or
L
N
Safety standards:
Installation precautions:
the connection cables must guarantee insulation up to
90 °C;
ensure a space of at least 10 mm between the case and
the nearby conductive parts;
digital and analogue input connections less than 30m
away; adopt suitable measures for separating the cables
so as to ensure compliance with the immunity standards;
Secure the connection cables of the outputs so as to avoid
contact with very low voltage parts.
Disposal of the product
The appliance (or the product) must be disposed of
separately in accordance with the local waste disposal
legislation in force.
-
electronic controller
Description
PJEZ* (models S, Y, C) represent a range of electronic microprocessor controllers with LED display developed for
the management of refrigerating units, display cabinets and showcases.
PJEZS*, designed for the management of static refrigerating units, no fan on the evaporator, operating at
temperature above 0°C;
PJEZY*, designed for the management of static refrigerating units, no fan, operating at low temperatures;
PJEZC*, designed for the managements of low temperature ventilated refrigerating units.
Technical specifications
power supply
rated power
inputs
relay outputs
type of probe
Fig. 1
connections
assembly
display
operating conditions
storage conditions
range of measurement
front panel index of protection
case
classification according to protection against
electric shock
environmental pollution
Fig. 2
PTI of the insulating material
period of stress across the insulating parts
category of resistance to heat and fire
immunity against voltage
type of action and disconnection
NTC
no. of relay automatic operating cycles
PROBES
DI
8
9 10 11
software class and structure
cleaning the instrument
cable max. length
WARNING:
do not run the power cable less than 3 cm from the bottom part of the device or from the probes;
the connections only use copper wires;
relay not allowed to use on fluorescent lamp(neon) with phase-shift capacitors.
Table of alarms
NTC
PROBES
DI
Alarm code
E0
E1(*)
Fig. 3
dr(*)
Lo
HI
EE
EF
(*)
not available for PJEZS*E*
IMPORTANT WARNINGS
The CAREL product is a state-of-the-art device, whose operation is specified in the technical documentation
supplied with the product or can be downloaded, even prior to purchase, from the website www.carel.com.The
customer (manufacturer, developer or installer of the final equipment) accepts all liability and risk relating to the
configuration of the product in order to reach the expected results in relation to the specific final installation and/
or equipment. The failure to complete such phase, which is required/indicated in the user manual, may cause
the final product to malfunction; CAREL accepts no liability in such cases. The customer must use the product
only in the manner described in the documentation relating to the product. The liability of CAREL in relation to its
products is specified in the CAREL general contract conditions, available on the website www.carel.com and/or by
specific agreements with customers.
230 Vac +10 /-15% 50/60 Hz; 115 Vac +10 /-15% 50/60 Hz
3.5 VA
NTC probes 1 or 2 inputs
1 digital input
30 A relay
UL: 16 A Res. 16 FLA 96 LRA - 240 Vac (FASTON tabs)
EN60730-1: 20(10) A 250 Vac (FASTON tabs)
UL: 12 A Res. 12 FLA 72 LRA - 240 Vac
EN60730-1: 12(10) A 250 Vac
8 A relay
UL: 8 A Res. 2 FLA 12 LRA - 240 Vac C300,
EN60730-1: 8(4) A NO, 6(4) A NC, 2(2) A CO - 250 Vac
5 A relay
UL: 5 A Res. 1 FLA 6 LRA - 240 Vac C300,
EN60730-1: 5(1) A - 250 Vac
Std CAREL NTC 10 KΩ at 25 °C
for screw terminals, cross-section of cables from 0.5 mm2 to 1.5 mm2, rated maximum
current per terminal 12A
for FASTON tabs, cross-section of cables up to 2.5 mm2, rated maximum current per
terminal 20A
use rear brackets
2 digit LED display with sign (-99 to 99) and decimal point; four status LEDs
-10T50 °C - humidity <90% rH non-condensing
-20T70 °C - humidity <90% rH non-condensing
-50T90 °C - resolution 0.1 °C
panel installation with IP65 type 1 gasket
plastic terminal, 81x26x65 mm
Class II when suitably integrated
normal
250V
long
category D (UL94 – V2)
category 1
1C relay contacts
100,000 operations
Class A
only use neutral detergents and water
probes: 30m, relay: 10m
LED
Description
ON
probe 1 error = control
ON
probe 2 error = defrost
ON
open door alarm
ON
low temperature alarm
ON
high temperature alarm
ON
unit parameter error
ON
operating parameter error
Parameters
involved
-
[d0 = 0 / 1]
[AL] [Ad][A0]
[AH] [Ad][A0]
-
-