device(fuse) in the positive lead. This pump requires a 15 amp fuse.
15. The pump circuit should not include any other electrical loads.
16. As the water supply pump is non-essential, reference the wire Chart under
the electrical information. Be sure to have the correct wire sizing for the length
of wire you are using.
17.After installation, check the voltage at the pump motor. Voltage should be
checked when the pump is operating. Full voltage must be available at the
pump motor at times.
Notes
1. Flexible potable water hose or PEX tubing is recommended instead of rigid
piping at the pump. If you choose to use rigid piping, provide a short length of
hose between the pipe and the pump to avoid noise and vibration.
2. We do not recommend the use of metal fittings. When possible, use the
provided plastic fittings.
3. Do not adjust the bypass personally without the help of a technician.
4. Lack of sanitizing and maintenance is one of the main reasons for the
underperformance of the pump. Please do maintenance and winterize the
pump at appropriate times, especially before and after a period of storage.