Download Print deze pagina

Hitachi Utopia IVX Premium Series Installatie- En Bedieningshandleiding pagina 14

Advertenties

Transportation and handling
N O T E
The label for the vessel under PED are attached on the high pres-
sure vessel. The pressure vessel capacity and vessel category
are indicated on the vessel.
Location of High Pressure Switch
5 TRANSPORTATION AND HANDLING
When hanging the unit, ensure a balance of the unit, check safety
and lift it up smoothly
Do not remove any packing materials.
Hang the unit under packing condition with two ropes.
For safety reasons ensure that the outdoor unit is lifted smoothly
and does not lean
Gross Weight
Model
(kg)
77
RAS-3HVNPE
116
RAS-(4-6)H(V)NPE
78
RAS-4H(V)NCE
6 BEFORE OPERATION
C A U T I O N
Supply electrical power to the system for approximately 12 hours be-
fore start-up or a long shutdown. Do not start the system immediately
after power supply, it may cause a compressor failure because the
compressor is not heated well.
When the system is started after a shutdown longer that approxi-
mately 3 months, it is recommended to check the system by your
service contractor.
7 REMOTE CONTROLLER
It is advisable to use PC-ART or PC-ARF remote controller (both optional). For more information about it installation and operation,
please refer to its corresponding Installation and Operation Manuals.
14
Compressor
Gross Weight
Model
RAS-(5-6)H(V)NCE
RAS-8HN(P/C)E
RAS-10HN(P/C)E
PMML0251A rev.2 - 02/2013
N O T E
The high pressure switch is indicated on the electrical wiring di-
agram in the outdoor unit as PSH connected to printed circuit
board (PCB1) in the outdoor unit
Contact Point
Connected to the electrical wire
D A N G E R
Do not change the high-pressure switch locally or change
the high pressure cut-out set value locally. If changed, it will
cause serious injury or death due to explosion.
Do not attempt to turn service valve rod beyond its stop.
RAS-3HVNP
RAS-(4-6)H(V)NCE
(kg)
90
149
151
Turn OFF the main switch when the system is to be stopped for a
long period of time: If the main switch is not turned OFF, electric-
ity will be used, because the oil heater is always energised during
compressor stopping.
Make sure that the outdoor unit is not covered with snow or ice.
If covered, remove it by using hot water (approximately 50°C). If
the water temperature is higher that 50 °C, it will cause damage
to plastic parts.
Structure of High Pressure Switch
Pressure Detected
RAS-(4-6)H(V)NPE
RAS-(8-10)HN(P/C)E
> 60º
0.7 -1.0 m

Advertenties

loading