3. Pipe disconnector
4. Cleaning compressor
5. Floor heating circuit
6. Connection hose
7. Drain hose
8. Stop valve
9. Drainage
Rinsing process:
1. Set the switch to Rinse.
2. Press the "ON/OFF"
cally.
When filling the compressed air reservoir, do not pull the electrical plug when the com-
pressor is running.
3. Open the water feed.
4. Press the program button "Water + Air (pulsing)"
5. The rinsing process is over when no more discharges are visible. For this it is recommended
that the water escaping from the tapping points be allowed to flow through a mesh with a
width of about 100 μl.
6. After the rinse, the rinse compressor must be turned off.
7. Then close the water feed.
8. Then disconnect the ROPULS from the power supply.
9. The compressor must not fill. The filling process (8 bar) must be completed. The rinsing ma-
chine must be separated from the test pipe, and all connections must be properly installed.
Then a leak test is necessary.
10. After the rinsing process, a rinsing log (certificate) must be made out. The original copy must
remain with the customer and the carbon copy with the company performing the work.
7

Installation and maintenance instructions for compressor

Starting Operation:
Check nameplate to ensure that indicated voltage agrees with supply voltage.
Insert plug in respective socket.
The plug coming with the equipment is a VDE 16A.
Operation of the compressor is automatically controlled by the pressure control, which
switches the compressor off once pressure in the tank has reached its maximum, while it
starts again when it has fallen to its minimum.
Proper automatic operation of the compressor is indicated by a compressed air blast when
the motor stops.
7.1

Operation and maintenance

Before you start working, let the compressor run for 10 minutes with the air tap completely open
so that its moving parts can get used to operating.
Important! Please read!
This compressor is not designed or built for long-term use. It is recommended that it not be op-
erated more than 15 minutes continuously.
Set-up: Always set up the compressor at least 50 cm from any obstruction that could
hinder the airflow and thereby the cooling
program button. The compressor fills the pressure vessel automati-
ENGLISH
. And perform the rinse.
21