the temperature of the exhaust
pipe is too low, the machine will
automatically enter protection
status; if the temperature of the
exhaust pipe rises to a certain
temperature, it can automatically
revert to normal operation.
2. Overflow Protection Function:
When water in the water pan
exceeds the warning level, the
machine will automatically sound
an alarm, and the "FULL" indicator
light will flash. At this point, you
need to move the drainage pipe
connecting the machine or the
water outlet to sewer or other
drainage area to empty the water
(details see DrainageInstructions at
the end of this chapter). After the
water is emptied, the machine will
automatically return to the original
state.
3. Automatic Defrosting (cooling
models have this function):
The machine has automatic
defrosting function.Defrosting can
be achieved through four - way
valve reversing.
4. Protection Function of the
Compressor:
To increase the service life of the
compressor, it has a 3-minute delay
booting protection function after
5. Installation and adjustment
Installation
Warning: before using the mobile air
conditioning, keep it upright for at
least two hours. The air conditioning
can be easily moved in the room.
In the moving process, ensure that
the air conditioning is in the upright
position and the air conditioning
should be placed on a flat surface. Do
not install and use the air conditioning
in the bathroom or other humid
environments.
1. Install the heat pipe assembly (as
shown in Fig.1)
Take out the outer connector
assembly and the exhaust pipe
assembly, and remove the plastic
bags;
Insert the heat pipe assembly (the
end of the exhaust joint) into the
back panel vent slot (push to the
left) and complete the assembly
(as shown in figure 1).
2. Installation of window sealing plate
components.
Half open the window, and mount
the window sealing plate assembly
to the window (as shown in Fig.2
and Fig.3).Components can be
placed in horizontal and vertical
direction.
Pull various components of the
window sealing plate assembly
open, adjust their opening distance
to bring both ends of the assembly
into contact with the window
frame, and fix various components
of the assembly.
3. Install the window sealing plate
assembly.
Notes: the flat end of the exhaust pipe
joints must be snapped into place. 2)
The pipe cannot be distorted nor has
substantial turning (greater than 45 °).
Keep the ventilation of the exhaust
pipe not blocked.
4. Install the body
Move the machine with installed heat
pipe and fittings before the window,
and the distance between the body
and walls or other objects shall be
least 50 cm (as shown in Fig.4).
– 10 –
-10-