5. Attaching the Terminal Box Cover

Close the terminal box using the terminal box cover set (#222022) (included). This cover is not installed at the factory
and is included in the scope of delivery. The rubber seal must be positioned between the cover and the cast basin. The
cover must be screwed on using the screws that are included.

6. Purging the Water Pipe

The water pipe must be thoroughly purged before it is connected to the water supply. It is possible for loose processing
residue to be located in newly laid pipes. The pipe valve on the watering basin also needs to be thoroughly purged
before initial operation.
7. Setting the Flow Rate on the Valve
The H10 heatable watering basin is fitted with a flow rate regulation screw at the installation elbow that enables regula-
tion of the water flow rate at the pipe valve. The regulation screw can be set using a no. 6 Allen key or a 10-cent coin
(one Eurocent).
Slot horizontal = maximum water flow
Slot vertical = minimum water flow
Caution:
!
Do not remove the regulation screw