12.3. Messages in the display

Error messages in the display 1
An error message indicates an electrical malfunction in the system.
The sauna control unit is no longer operational.
1. Note the error message.
2. Switch off the sauna control unit.
3. Switch off the main fuse of the sauna control unit in the fuse box.
4. Contact customer service.
Error
Description
E-F1
Short circuit/broken wire/
heater sensor defective
E-24
Broken wire or damage
to the excess tempera-
ture fuse.
E-PI
Damage in the potenti-
ometer for the tempera-
ture setting.
E-51
PLUS/MINUS time but-
E-52
tons or START/STOP
E-53
button blocked
Status messages in the display 1
LL
The interior temperature is under 0 °C
HH
The interior temperature is above 140 °C
WORLD OF WELLNESS
Cause / rectification
See point 5. Troubleshooting for the
installer on page 15
See point 5. Troubleshooting for the
installer on page 15
See point 5. Troubleshooting for the
installer on page 15
Remove cover and control panel, setup
buttons, put control panel and cover back
on.
p. 25/28