Download Inhoudsopgave Inhoud Print deze pagina

Cleaning The Hygienic Exhaust Filter; Spare Parts And Accessories; Before You Send In The Appliance - Dirt Devil BLACK LABEL CP-2 Bedieningshandleiding

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 22
5 Maintenance

5.4 Cleaning the hygienic exhaust filter

13
14

5.5 Spare parts and accessories

ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have purchased by reordering.
Ordering address:
Page 48, "International Service"
Further information:
www.dirtdevil.de
The adjacent accessory parts and spare parts can be reordered.

5.6 Before you send in the appliance

WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing
Chapter 4.3, "Switching off".
Before contacting your authorised Royal dealer, Royal service partner or
appliance market or sending in the appliance, first follow the procedure in
the following table to check if you can solve the problem yourself.
NOTE:
If you were unable to solve the problem with the information in the above
table, contact Customer Service ( Page 48, "International Service").
Problem
The appliance
The socket does not carry current.
will not start.
Test the vacuum cleaner at another socket which you
are sure carries current.
Power cord is damaged. Have the cord replaced by the
Royal Appliance Customer Service, address
48, "International Service".
The vacuum
The overheating protection has tripped (possibly due
cleaner stops
to blocked suction channels, filters, or similar).
suddenly.
Switch the appliance off and pull the plug out of the
socket. Remove the cause of overheating (e.g. by dis-
assembling telescopic tube and suction hose and re-
moving the obstacle and/or cleaning filters). Wait for
about 45 minutes. After the appliance has cooled off,
you may switch it on again.
A
A
Solution
B
It is best to check/clean the hygienic exhaust filter each time you clean
the dual motor protection filter,
protection filter".
1. Switch off the appliance,
2. Slide the release catch of the exhaust filter cover to the right (Fig. 13/A)
and open the exhaust filter cover.
3. Remove the hygienic exhaust filter (Fig. 13/B).
4. Tap the dirt out of the hygienic exhaust filter over a dustbin.
5. Remove residual dust with a soft brush, e.g. the supplied furniture
brush.
6. If the hygienic exhaust filter is still dirty after this procedure, thoroughly
rinse it by hand in running water until all dirt is gone.
ATTENTION:
B
The filter is washable, but it may not be cleaned in dishwashers or
washing machines. Also, do not use detergents or brushes with hard
bristles to clean the filters. Let the filter dry for approx. 24 hours at room
temperature after washing it. Only put it back in place when it is
completely dry.
7. If the exhaust filter is damaged, deformed or too soiled, replace it
(ordering information
8. Place the clean/new exhaust filter back into its receptacle (Fig. 14/A).
9. Fit the exhaust filter cover on the bottom first and then pivot it in
upwards into place (Fig. 14/B).
Item number
2838001
Dual motor protection filter consisting of:
1 foam plastic filter element and 1 filter holder
2838002
1 hygienic exhaust filter
M203-5
1 parquet brush
M209
1 turbo brush
M219
1 mini turbo brush
M232
1 long, flexible crevice nozzle
Problem
The cleaning re-
The bypass vent (Fig. 1/26) is open.
sults are unsat-
Close the bypass vent (Fig. 1/26).
isfactory in spite
The attached nozzle is unsuitable.
of the appliance
Change the nozzle,
working correct-
proper nozzle".
ly.
The position of the "carpet/hard floor" selector (Fig. 1/
2) is unsuitable. Set the "carpet/hard floor" selector
(Fig. 1/2) to the correct position for the type of floor,
The dust container is full.
Empty the dust container,
the dust container".
The filters are dirty. Clean the respective filter
clone unit" or
haust filter".
Page
When vacuum-
The pressure in the vacuum cleaner became too low
ing with the long,
and caused the safety valve to trigger.
flexible crevice
Open the bypass vent until the valve no longer trig-
nozzle, there is
gers.
suddenly a high-
pitched whistling
and the suction
power drops
considerably.
Chapter 5.3, "Cleaning the dual motor
Chapter 4.3, "Switching off".
Chapter 5.5, "Spare parts and accessories").
Description
Solution
Chapter 3.2, "Selecting the
Chapter 4.2, "Vacuum cleaning", step 4.
Chapter 5.1, "Emptying
Chapter 5.2, "Cleaning the dust container and cy-
Chapter 5.4, "Cleaning the hygienic ex-
15

Advertenties

Inhoudsopgave
loading

Inhoudsopgave