Download Inhoudsopgave Inhoud Print deze pagina

General Description; Connections And Recommendations - GYS NOMADFEED 425-4 Handleiding

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 42

GENERAL DESCRIPTION

NOMADFEED is a mobile MIG/MAG/Open-Arc wire feed case. The plastic casing makes it naturally electrically insulated and it also has the IP23 pro-
tection rating meaning it is protected against water projections and external elements. It powers itself by using the voltage available on the welding
circuit. This voltage can come from a current source (CC), a voltage source (CV), an alternative signal, a positive direct signal or negative direct signal.
NOMADFEED pilots the arrival of the gas, the welding current and wire feeding. The welding current, welding voltage, wire feeding speed and power
supply voltage are displayed.
The powerful wire feed motor assembly has 4 drive rolls and is suitable for standard and cored/flux wire up to 2.4mm thick..
EQUIPMENT DESCRIPTION (FIG-1)
1-
Wire feeder motor
2-
Earth clamp connection cable
3-
2 times / 4 times switch
4-
Main switch
5-
Wire speed potentiometer
6-
Protection "feet"
7-
Control panel
8-
Reel support
MAN MACHINE INTERFACE (MMI) (FIG 2)
Nomadfeed 425-4
L01 - Wire speed display indicator
L02 - Welding current display indicator
L03 - Welding voltage display indicator
L04 - Power supply voltage display indicator
L05 - Overheating indicator
L06 - Overvoltage indicator
L07 - Voltage at torch indicator
L08 - 3 digits welding or power supply voltage
L09 - 3 digits welding current or feeding speed diplay

CONNECTIONS AND RECOMMENDATIONS

Make sure the welding generator is switched off when connecting or disconnecting the wire feeder.
The unit is powered by connecting the power cable in the case to a welding generator. You must choose the polarity based on the type of wire used.
The welding cable potential will be the same as the welding torch.
Connect the second polarity of the generator to the piece to weld.
The connection between these two elements is done via one of the following connection cables :
Designation
NOMAD CABLE
NOMADFEED
9-
Protection fuse
10-
Gas purge button
11-
Wire feed button
12-
Selection of «Soft Start» mode
13-
Selection of CC or CV mode
14-
Arrival of gas
15-
Power supply cable
+
-
Cooling
AIR
Length
Section
5m (16 ft)
10m (32 ft)
Ø 95mm²
(3/0 AWG)
15m (49 ft)
20m (66 ft)
EN
Reference
032439
032446
036666
036673
13

Advertenties

Inhoudsopgave
loading

Inhoudsopgave