Labels / Etiketten / Etiketten / Étiquettes / Etiquetas /
Etiquetas / Etichette
DIP Switch Tables
Serial
SW Function
ON
OFF
1-1 Data receive error Ignored
Prints "?"
1-2 Receive buffer
45 bytes
4 KB
capacity
1-3 Handshaking
XON/XOFF
DTR/DSR
1-4 Data word length 7 bits
8 bits
1-5 Parity check
Enabled
Disabled
1-6 Parity selection
Even
Odd
1-7
Transmission speed (See table below.)
1-8
2-1 Handshaking
Receive
Offline or Receive
(BUSY condition)
buffer full
buffer full
2-2 Customer display
Connected Not connected
connection
2-3
Print density
See Table A.
2-4
2-5
Internal use. Fixed to Off.
2-6
2-7 I/F pin 6 reset
Enabled
Disabled
2-8 I/F pin 25 reset
Enabled
Disabled
Transmission speed (bps)-bits per second
4800
9600
19200
38400
Parallel
SW
Function
ON
1-1
Auto line feed
Always
enabled
1-2
Receive buffer
45 bytes
capacity
1-3~
Reserved. Fixed to Off.
1-8
2-1
Handshaking
Receive
(BUSY condition)
buffer full
2-2
Internal use. Do not change setting. Fixed to Off.
2-3
Print density
See Table A.
2-4
2-5
Internal use. Fixed to Off.
2-6
2-7
Reserved (for serial interface) Fixed to Off.
2-8
I/F pin 31 reset signal. Do not change setting.
Fixed to On.
Table A
Print density/low power
1 Print density (Light)
2
1-7
1-8
3
ON
ON
4 Print density (Dark)
OFF ON
ON
OFF
OFF OFF
OFF
Always disabled
4 KB
Offline or Receive
buffer full
SW 2-3
SW 2-4
ON
ON
OFF
OFF
ON
OFF
OFF
ON