TROUBLESHOOTING (continued)
PROBLEM
TUB LOSES AIR
• Air valve cap loose.
PRESSURE
• Air valve base loose.
• Hole, cut or split on spa tub.
LEAKING BETWEEN
• Spa control base inlet/outlet
SPA TUB
connections not securely tight.
CONNECTORS AND
• Spa control base inlet/outlet o-ring
CONTROL UNIT
missing/dirty.
CONNECTORS
SPA IS TOO NOISY
• Control base components not securely
IN FILTRATION
attached.
MODE ONLY
• Control base ground not level and fi rm.
• Spa fi lter motor failed.
INSUFFICIENT
• Insuffi cient operating time of the
CHLORINE
sanitation system and/or heater is
running at the same time.
• Chlorine loss due to intense sunlight
exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
BUBBLE AIR
• Air blower pump is too hot.
BLOWER DOES NOT
WORK
AIR PRESSURE
• Hose adaptor o-ring missing.
IS WEAK DURING
• Infl ation hose adaptor not securely
INFLATION
tighten.
• Connection between the hose
adaptor and blower infl ation outlet,
and between the infl ation hose and
infl ation valve are loose.
• Air blower failure.
AIR BUBBLES ARE
• O-ring missing between the control
NOT AS STRONG
base air outlet and spa tub air inlet
AS BEFORE
connections.
• Air connection nut is not securely
tight.
• Air bubble channel passage inside the
tub broken or leaking.
• Air blower failure.
S AVE THESE INSTRUCTIONS
(351IO) SPA (JET + BUBBLE) ENGLISH 7.5" X 10.3" PANTONE 295U 04/18/2022
CAUSE
• Ensure air valve cap is securely closed.
• Fill up the spa tub with air then make sure the
• Put liquid soap and water in a squirt bottle and
• Tighten inlet and outlet connections.
• Coat the o-ring with petroleum jelly for water proof.
• Remove grid from inside spa with a screwdriver,
• Ensure control panel, back cover and all inlet/
• Ensure ground is level, fi rm and smooth.
• Replace the failed fi lter motor with a new one.
• Increase the sanitation system operating time
• Use a SPA cover when the SPA is not in use and/
• Increase the sanitation system operating time and
• Check and clean the cell if necessary. See
• Turn off and unplug the spa. Let it cool down and
• If problem persists, contact Intex Service Center.
• Ensure the o-ring is in place.
• Tighten/reinstall hose adaptor.
• Finger tighten during infl ation.
• If problem persists, contact Intex Service Center.
• Ensure the o-ring is in place.
• Finger tighten all nuts.
• Use repair patch to repair any puncture.
• If problem persists, contact Intex Service Center.
SOLUTION
air valve base is tighten, see "Spa Tub Air Valve
Fastening" section.
spray on seams. If there is a leak it will bubble.
After you fi nd the leak, clean and dry the leaking
area, then apply the repair patch that comes with
your spa.
ensure inlet/outlet O-ring is in place, clean and not
damaged.
outlet are securely connected.
and ensure the heater is off during the sanitation
process. See "Sanitation System Operating
Instructions".
or when the sanitation system is operating.
test the water using the test strips. See "Sanitation
System Operating Instructions".
"Maintenance".
restart all over again.