the fragrance container before refilling to prevent water getting into it.
Should this nevertheless occur, it will be necessary to remove the water
container (2) and rinse it. Fragrances should not be permitted to enter the
water tank, since they might destroy the plastic.
Important information
Humidification with an evaporator takes time. This means that it usually
takes more than 2–3 hours to reach the desired humidity. If you operate the
humidifier in a very dry environment we recommend to operate it on speed
level 2 to reach a maximum amount of humidity in a short time.
Cleaning and cassette replacement
Prior to any maintenance work and after each use, switch off the appliance
and withdraw the mains cable from the socket.
Never immerse in water (risk of short circuit).
• External surfaces should only be wiped off with a damp cloth and then
dried well.
• Every 2 weeks: To clean the inside, remove the filter cassette and descale
the lower part if necessary. After descaling, thoroughly rinse the lower
part and then dry it before putting the air humidifier into operation again.
• For hygienic and optimum operation of the air humidifier, the filter cas-
sette must be replaced every 2 – 3 months. If the filter cassette remains in
use for longer than this, on the one hand the humidity output may decline
severely and on the other, the anti-bacterial action of the cassette can no
longer be guaranteed. The filter cassette can be obtained from the dealer
where you purchased your Oskar little.
Ionic Silver Cube ™
The Ionic Silver Cube (13) prevents the growth of germs and bacteria in the
humidifier due to the continuous release of silver ions. The use of the Ionic
Silver Cube leads to a hygienic room climate. The lifetime of the Ionic Silver
Cube is around one year. We therefore recommend that you replace the Ionic
Silver Cube at the beginning of every humidifying season. The Ionic Silver
Cube starts working as soon as it comes into contact with water, and also
works when the unit is switched off.
Repairs
• Repairs to electrical appliances must only be carried out by a qualified
electrical technician. If improper repairs are carried out, the warranty
lapses and all liability is refused.
• Never operate the appliance if the adaptor or plug is damaged, after it has
malfunctioned, if it has been dropped or has been damaged in any other
way (cracks/breaks in the casing).
• Do not push any object into the appliance.
• If the appliance is beyond repair, make it unusable immediately by cutting
through the cable and hand it in at the collection point provided for the
purpose.
Disposal
The European directive 2012 / 19 / CE on Waste Electrical and Electronic
Equipment (WEEE), requires that old household electrical appliances must