3. Electric Wiring Diagram
Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Rated Residual
Action Current mA
Fuse
A
Power Cord
(mm
Signal cable
(mm
※ Above data is subject to modification without notice.
Note:
The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire
diameter must be increased. The signal cable can be extended to 50m at most.
4. Installation instruction and requirement
The heat pump must be installed by a professional team. The users are not
qualified to install by themselves, otherwise the heat pump might be damaged
and risky for users' safety.
A. Installation
1) The inlet and outlet water unions can't bear the weight of soft pipes. The
heat pump must be connected with hard pipes!
2) In order to guarantee the heating efficiency, the water pipe length should
be ≤10m between the pool and the heat pump.
IKARIA-R
INVERTER 5
8.0
30
8.0
2
3×1.5
)
2
)
3×0.5
IKARIA-R
IKARIA-R
INVERTER 6
INVERTER 9
9.5
15.0
30
30
9.5
15.0
3×1.5
3×2.5
3×0.5
3×0.5
8
IKARIA-R
IKARIA-R
INVERTER 12
INVERTER 14
20.5
23.5
30
30
20.5
23.5
3×4
3×6
3×0.5
3×0.5
IKARIA-R
INVERTER 17
24.0
30
24.0
3×6
3×0.5