10-Installation
Note: Keep in safe place
Keep the transportation bolts in a safe place for later use. Whenever the appliance is to
10.4 Moving the appliance
If the machine is to be moved to a distant location, replace the transportation bolts re-
moved before installation to prevent damage:
1. Remove the blanking plugs.
2. Remove the back cover.
3. Insert the plastic spacers and the transportation bolts.
4. Tighten the bolts with a spanner.
5. Replace the back cover.
10-6
10.6 Drain w ater connection
Fix the water drain hose properly to the piping. The hose has to reach at one point a height
between 80 and 100 cm above the appliance bottom line! If possible keep always drain
WARNING!
Use only the supplied hose set for the connection.
Never reuse old hose sets!
Only connect to cold water supply.
Before connection, check whether the water is clean and clear.
26
10.5 Aligning the appliance
Adjust all feet (Fig. 10-6) to achieve a complete level
position. This will minimize vibrations and thus noise
during use. It will also reduce wear and tear. We recom-
mend to use a spirit level for adjustment. Floor should
be as stable and flat as possible.
1. Loose the locknut (1) by using a wrench.
2. Adjust the high by turning the foot (2).
3. Tighten locknut (1) against the housing.
GB