OPERATION
Opens and closes automatically via infrared presence detection of the hands.
The electronic soap dispenser is compatible with:
• Vegetable-based liquid soap with a maximum viscosity of 3,000 mPa.s.
• Dedicated foam soap: cf. INSTALLATION section > Switch to foam soap mode.
• Hydroalcoholic gel (DELABIE dispensers without tanks type 512111, 512121, 512131, 512136,
512141, 512146, 512151, 512171 are not compatible).
On compatible models our mechanisms work with World Health Organistion (WHO) recommended
hydroalcoholic solutions composed of the following: ethanol, 3% hydrogen peroxide, glycerol, purified
water. Any other additives can cause the pump to malfunction, requiring more frequent maintenance.
POWER SUPPLY
• On mains supply models: electrical supply 100-240V/50-60Hz class II SELV (without earth connection).
• On battery operated models: 4 batteries 1.5V
• The installation must comply with current regulations in your country.
• If the power supply cable is damaged, it must be replaced by the installer.
• Make sure the cables are secured in place by clamps or a rigid sheath.
INSTALLATION
Sections 1, 2, 3: Installing the spout
To prevent interference from infrared rays, do not install a reflective object in the sensor's detection zone.
• Cross wall models cf. pages 20-21 and wall-mounted models cf. pages 22-23: install the dispenser
at least 165mm above the washbasin.
• Deck-mounted models cf. pages 24-25.
Section 4: Installing the housing (pages 26-27)
Do not install the housing above the level of the spout (Fig. J page 26).
Section 5: Priming the pump (page 27)
Press and hold the button a (Fig. S):
• If the soap comes out of the spout in less than 10 seconds, release the button a (Fig. S) to stop
it priming.
• If the soap does not come out of the spout after 10 seconds of pressing the button, release the button
a (Fig. S). Priming will continue. Once the soap comes out of the spout, press the button a (Fig. S)
again or wave a hand in front of the sensor to stop it priming.
Section 6: Switch to foam soap (page 28)
• Remove the jumper located inside the housing cover (Fig. V) and place it on the pins in the box using
a pair of pliers (Fig. W)
• Change the diffuser for the one in the box (Fig. Y to AA)
Only use dedicated foam soap.
Section 7: Removing the tank (Fig. AB page 28).
4