2. Your product
Other than the heater you have chosen the package includes (picture 1):
- N° 1 metal brackets for wall mounting (fixed to the radiator);
- N° 4 nylon plug expansion 8x50mm;
- N° 4 5x60mm cross head screws to fix wall brackets;
- N° 2 bars for towels;
- N° 4 3,9x13mm screws to fix the bars to the heater.
Refer to your dealer is something is broken or missing.

3. Wall mounting

Only fix the heater in vertical position;
This heater is fitted with a double electrical insulation circuit (class II) and therefore does not require an earth connection.
This heater must be correctly installed in compliance with the regulations in force in the country of installation.
In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the floor. The
electrical connection to the power supply must also be fitted with a two-pole switch with a minimum gap between the
contacts that allows complete disconnection according to excess voltage III category conditions.
If you want to fix one or both towel rails to the product, before fixing the appliance to the wall bracket use the supplied
screws as illustrated in picture 3.
Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 4. Never install
the product so that the distance between the floor and the lower side of the product is less than 30cm:
-
Remove the wall-mounting bracket fixed to the back of the radiator, by releasing the 2 lower springs;
-
Use a pencil to mark the position of the fixing points (picture 5).
-
Drill the 4 holes at the points marked previously, and insert the plastic anchors;
-
Fix the bracket to the wall using the 4 screws supplied (picture 6);
-
Hook the radiator to the bracket starting with the 2 upper fixing points, and then click the 2 lower fixing points into
position (picture 7);
-
Should you have to remove the radiator from the bracket at a later stage, we recommend releasing the lower two
fixing points first and then the upper fixings.
4.
TOWELS
Always outspread the towels over the support bars (picture 8-A);
Do not place the towels on top of the product (picture 8-B);
Do not roll up the towels between the bar and the front surface (picture 8-C).

5. Command description and functioning

The following controls are available on the front panel (picture 9):
A -
Stand-by
B -
Increase
C -
Decrease
D -
Mode
E -
Display
The product can be operated in 3 different modes: automatic, programmed or frost free.
Automatic Mode
In this mode the product works to reach and maintain the Comfort temperature set by the user. An automatic power manage-
ment system allows optimum control of consumption and precise adjustment of the comfort level automatically maintaining the
selected temperature constant over time, in accordance with what has been set on the electronic thermostat.
In automatic mode is also available a special feature, which is activated at user's choice, which allows to detect the possible
opening of a window and force the functioning to the Frost free mode to minimize energy waste.
Programmed Mode
The product can be programmed, on hour base, for each day of the week. For each hour of the day it is possible to define
the reference temperature to be reached/maintained, choosing between Comfort, Eco (whose value is equal to the Comfort
temperature reduced by 3,5°C) or Frost free.