Download Print deze pagina

Kärcher Senso Timer ST6 eco!ogic Gebruiksaanwijzing pagina 21

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 60
1
2
.
.
1
1
1
 Note: The operating mode is specified and saved during the teaching process. A
change of the operating mode (e.g. from sensor control to time control) is only possible
by a new teaching process after a reset.
1
Note: In order to change the operating mode of an outlet or to add a sensor, the teaching
process must be restarted.
A reset must be performed for this purpose. The setting process is restarted, beginning with
sensor 1:
 Remove the batteries from both sensors and the control unit.
 Reinsert the battery in the control unit. As soon as the symbols appear on the display,
press the OK button until the time on the display is flashing.
 Reset the time and start the teaching process of sensor 1, then of sensor
2.
* depending on model
Preparation / teaching sensor
 Remove the sensor cap of the sensor.
 Connect the battery with the battery clip. The con-
nected battery is reinserted in the casing with the
3
.
battery clip going in first.
 Close the sensor by means of the sensor cap.
Note: The battery is not included in the scope of deliv-
ery.
 As soon as the contact of the radio signal is estab-
lished, the symbol for the radio signal appears per-
manently. It is now guided through the setup se-
quence (preset value for moisture, times, etc.).
 Sensor 1 was detected successfully.
*
*
*
2
2
2
Prepare / teaching sensor 2*
*
2
 The setting process of sensor 2 starts automatical-
ly after the watering setting of water outlet 1. If the
water outlet 1 remains inactive, teaching of the wa-
ter outlet 2 must be enabled by pressing the OK
button. The seconds countdown starts for water
outlet 2. Teaching of sensor 2 is equivalent to sen-
sor 1.