Safety considerations:
This device can be set for 2 overload trigger points
which can be set separately. For a safety function each
of them is a single channel considered as a "well tried
component" by Tractel
For a safety device with single channel, PL level is
determined by MTTF D (mean time between dangerous
failure) emanating from B
B10d:
According the technical data of the switch, the
life duration is determined by maximum switching
operations. Tractel
for switching inductive load of 2 A (eg: contactor coil).
NOTE: B
10d
is reduced.
MTTF
:
D
MTTF
must be evaluated by the integrator using the
D
formulas and diagrams of the standard EN ISO 13849-1
considering the B10d and category mentioned above
with
= the average number of hours of use per day
d
op

3.5. Designation, characteristics and outline dimensions

Code
Type
Mecha 3.2
293599
4. Installation of load limiter dynasafe
Product must be installed by a qualified technician.
4.1. Parts list of load limiter and its
environment
See figure 2.
8
Load (A)
Voltage (max)
250 VAC
5 (0.75 pf)
250 VAC
5
0 - 15 VDC
5
15 - 30 VDC
5
®
.
monitoring.
10D
considers B is 10.000 operations
®
can be better if the inductive load
where
Wire rope
Capacity daN
diameter mm
From 5 to 16
From 200 to 3200
Mecha 3.2
Inductive load (A) Approval
UL1054/CSA 22.2 No. 55 - 6.000 operations - 65° C
EN61058-1, T85, 10.000 operations
2
General rating - 50.000 operations (85° C)
3
General rating - 50.000 operations (85° C)
3
= the average number of days of use per year
h
op
= is the average time of use between the start of
t
cycle
two successive cycles of the component dynasafe
Mecha 3.2 in this case.
d
, h
and t
op
op
cycle
user.
Then, the MTTF
medium or high as proposed by EN ISO 13849-1 in
table 4
Denotation of
each channel
Low
Medium
High
Achieved PL:
After that, achieved PL is issued out by a diagram (figure
5 in EN ISO 13849-1) taking in consideration category,
DC monitoring capability and MTTF
detection DC factor is 'none' (no diagnostic coverage
possibility).
DANGER: The integrator must take care that
the inductive load could damage the device and
could reduce the electrical life duration. We strongly
recommend not to exceed an apparent power of 80VA
with 48VAC voltage max.
Width
Length
mm
112
TM
Connecting cable
1
Cable gland
2
Adjustment screw and nutlock
3
Assembling pin
4
Nameplate
5
Guide
6
Switch cover
7
Mobile half clamp
8
have to be defined by the installation
could be classified in a range: Low,
D
MTTF
D
Range of
each channel
3 years ≤ MTTF
< 10 years
D
10 years ≤ MTTF
< 30 years
D
30 years ≤ MTTF
≤ 100 years
D
. Without failure
D
Thickness
mm
mm
160
48
TM
Weight
kg
0.9

Advertenties