English
‧ Protect the mains socket and mains plug against moisture and wetness. A drip
loop must be formed with the mains cable. This prevents any water running along
the cable to the mains socket, which would result in a short-circuit.
‧ The electrical data of the appliance must match the data of the power mains. This
data is found on the type plate, the packaging and in these instructions.
Commissioning
Connecting the hose
1. Use a saw to shorten the connecting piece to the diameter of your hose (⌦A).
2. Screw the connecting piece onto the pump.
3. Connect your hose to the connecting piece.
Installing suction devices
1. Screw the suction devices into the openings of the body of the engine (⌦B).
Hint: Moisten the suction devices with water for easier installation.
Installing the pump cover for external use
The pump can be used inside and outside of the aquarium. Among the benefits of the pump cover ③ for
external use is that it allows the connection of an inlet hose.
1. Loosen and remove the two lateral fastening screws ① (⌦C).
2. Pull the pump cover ② with integrated power controller out of the engine body from the front.
3. Push the pump cover ③ into the engine body (⌦D).
4. Tighten the pump cover with the locking ring (⌦E).
20
Drip Loop