Before each fault elimination:
− switch off device
− wait for standstill of the beater
− pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Problem
Motor does not start.
Unusual vibrations
Device starts but blocks under
slight load and cuts off automat-
ically.
Model
Year of construction
Motor power P
1
MotorMotor
Speed n
0
(with speed control)
Beater diameter
Beater chuck
Beater length
Hand/arm vibration on the handle
(according to EN 1033/DIN 45675)
Volume of the material to be mixed
Weight
Sound power level L
WA
(as per EN ISO 3744)
Sound pressure level L
PA
(as per EN ISO 3744)
Safety classSafety class
Protection class
13
P
o
s
P
o
s
Possible cause
⇒ No power supply (power failure)
⇒ Mains cable defective.
⇒ Motor or switch defect
⇒ Beater defective.
⇒ Chuck defective.
⇒ Non-intended material to be mixed.
⇒ Extension cable too long, or cross-
section too small.
⇒ Socket too far away from main connec-
tion, and cross-section of connection
lead too small.
T
e
c
h
T
e
c
Measured sound power level L
s
i
b
l
e
f
a
u
l
t
s
s
i
b
l
e
f
a
u
l
t
s
Remedy
⇒ Check fuses (10 A)
⇒ exchange defect cable, respectively check
extension cable, (by electrician)
Never use defect lead
⇒ To correct the problem, refer to the manufac-
turer or other approved service centre.
⇒ Replace the beater.
⇒ To correct the problem, refer to the manufac-
turer or other approved service centre.
⇒ Incorrect processing. Follow the processing
instructions from the supplier.
Extension cable at least 1,5 mm2 , maximum 25
m long.
Cross- section of at least 2,5 mm 2 in longer
cables.
n
i
c
a
l
d
a
t
a
h
n
i
c
a
l
d
a
t
a
Profi RW 1400-2
see last page
1400 W
AC-motor 230 V ~ 50 Hz
1. speed: 150 - 300 rpm
2. speed: 300 - 650 rpm
140 mm
ca. 600 mm
a
= < 1,69 m/s²; K = 1,5 m/s²
h,D
< 65 Liter
7,0 kg
85,8 dB (A); K
Profi RW 1800-2
1800 W
160 mm
M 14
< 90 Liter
7,5 kg
96,8 dB (A); K
= 3 dB (A)
WA
WA
= 3 dB (A)
pA
II /
IP 20