5.
Controller cool control
Temperature controller cool control with touch display for controlling 12 or 24 volt DC fans with barrel
connector (5.5 mm x 2.1 mm). The Aqua Medic temperature controller cool control is equipped with a
saltwater-proof temperature sensor as standard and is ready for connection.
5.1. Fan
A 12 or 24 V DC fan with a barrel connector (5.5 mm x 2.1 mm) can be connected. The power pack of the fan
is connected to the corresponding connection on the controller (Fig. 1, No. 5) as a power supply, the fan is
connected to the power output of the controller (Fig. 1, No. 6).

5.2. Description of the front panel

Fig. 1: cool control
1. Fan power
2. Nominal value + set
3. Actual value
4. Temperature sensor
5. Power supply 12 or 24 V DC. Socket for barrel connector (5.5 mm x 2.1 mm)
6. Connection for fan with a barrel connector (5.5 mm x 2.1 mm)
7. Arrow key to adjust the parameter
8. Arrow key to adjust the parameter
9. „On/Off" button

5.3. Technical Data

Display:
Adjustment range:
Resolution:
Adjustment accuracy:
Loading capacity of contact:
Humidity:
Power supply:
Dimensions:
5.4. Operation
A) ON / OFF setting (Fig. 1, No. 9)
When switched off, press briefly to switch on; when switched on, press briefly to switch off. If the power supply
was interrupted, the switch has to be tapped again to switch the unit on.
0 – 36 °C
-20 - 50 °C
0.1 °C
0.5 °C
max. 65 W
below 80%
12 or 24 V DC
120 x 62 x 28 mm