Installation - for contractors

8. Appliance description

8.1
Appliance layout
1
1 Natural stone panel
2 Wall mounting brackets with fixing screws
3 Power cable
4 Spacer studs
Note
The hexagon screws for wall mounting are not in-
cluded in the standard delivery.
A heating conductor, featuring 2 safety temperature lim-
iters with automatic reset, is laid in a duct system milled
into the back of the natural stone panels. The duct system
is then filled with marble adhesive which acts as a cover.
8.2 Standard delivery
The following are delivered with the appliance:
◦ 3 Wall mounting brackets with fixing screws
◦ 1 Spacer stud
◦ NSH 35-115: 1 Reflector panel
◦ NSH 145-165: 2 Reflector panels

8.3 Special accessories

The natural stone heater is controlled via the room tem-
perature controller.
◦ RT 600: Room temperature controller with thermal
feedback, breaking capacity 10 A / 230 V
◦ RT 601 SN: Room temperature controller with ther-
mal feedback, with ON/OFF switch, breaking capaci-
ty 10 A / 230 V, installation on finished walls
◦ RT 5050 SN: Room temperature controller with ther-
mal feedback, with ON/OFF switch, breaking capaci-
ty 10 A / 230 V, installation on unfinished walls
◦ RTE 900 SN: Electronic 2-point controller with ON/
OFF switch, breaking capacity 16 A / 230 V, installa-
tion on finished walls
◦ RTE 5050 SN: Electronic 2-point controller with ON/
OFF switch, breaking capacity 16 A / 230 V, installa-
tion on unfinished walls
◦ RTF: Digital, wireless room temperature controller
with 7-day program, 5 available operating modes
14
2
3
4

9. Preparations

9.1
Installation site
The natural stone heater is intended solely for permanent
wall mounting. Ensure the wall offers adequate load-bear-
ing capacity.
It can be installed in any room. In bathrooms, the natural
stone heater can be mounted in safety zone 2 (not the
mains junction box).

9.2 Aligning the appliance

The natural stone heater is configured at the factory for
horizontal installation.
If you want to install it vertically, make the following chang-
es before beginning installation:
» Replace the wall mounting bracket above the power
cable with the diagonally positioned spacer stud.
WARNING Electrocution
Ensure that the power cable is always located at the
lower edge.
» Rotate both wall mounting brackets with the slot ap-
ertures downwards.
Material losses
!
Carefully tighten the fixing screws in the natural
stone heater, as otherwise the rawl plugs in the nat-
ural stone panel may over-rotate and become loose.

9.3 Mounting the reflector panel

Depending on size, the appliance is delivered with 1-2 re-
flector panels made from aluminium-coated EPS. Reflec-
tor panels have insulating as well as reflecting properties
and reduce heat loss through the wall.
If you are installing your appliance on an external wall, we
recommend mounting the reflector panel at the installa-
tion site before fitting the appliance.
Note
The aluminium coating of the reflector panel will rub
off slightly.
» Wear protective gloves when mounting the re-
flector panel.
» Use a suitable adhesive (wall adhesive) and a
notched trowel with medium sized notches (B2 or B3)
for mounting the reflector panel.
» Apply the adhesive to the entire rear surface of the
reflector panel.

Advertenties