INSTALLATIoN

Installation
9.
Installation
9.1

Dismantling the casing cover

f Undo the 2 internal torx screws with a torx screwdriver 25,
turning it clockwise as far as it will go.
The torx screws are rotated into the casing and remain in the
casing.

9.1.1 Connecting the appliance back panel and casing cover

Note
The casing cover has 2 internal fixing eyes at the top,
which are hooked into place in the 2 hooks on the appli-
ance back panel.
1
1 Hook
2 Fixing eye

9.1.2 Removing the casing cover

2.
1.
16
| Ultronic S/W
f Detach the casing cover from the appliance at the bottom.
f Lift the casing cover up until the cover's fixing eyes have
come free of the hooks on the appliance back panel.
f Pull the casing cover forwards to remove it from the
appliance.
9.2

Wall mounting

You can find a drilling template in the appendix to these instruc-
tions.
f When positioning the drilling template, be aware of the lo-
cation and length of the power cable (see chapter "Electrical
connections / Power cable").
f Use our standard values as a guide for the installation height
(see chapter "Specification / Standard values for the installa-
tion height").
f Use suitable fixing screws and rawl plugs.
f Cut out the drilling template and mark the 4 fixing points on
the wall.
2
f Drill the 4 holes and insert rawl plugs.
f Screw the 2 lower fixing screws into the wall.
9.3

Power supply

WARNING Electrocution
Only use a permanent connection to the power supply.
The appliance must be able to be separated from the
power supply by an isolator that disconnects all poles
with at least 3 mm contact separation.
9.3.1 Power cable
The length of the power cable must be at least 100 mm.
The individual wires of the power cable must be stripped ap-
prox. 6.5 mm so they can be connected to the mains terminal.