Overview
2. Installation in a non-ducted configuration.
Unheated location at temperatures above 5°C and isolated from the
heated rooms of the house.
"Ducting" setting to be set to "Interior/Interior"
Recommended location = underground or semi-underground, room where
the temperature is higher than 10°C all year round.
Examples of locations:
• Garage: recovery of free calories released from appliances in operation.
• Laundry room: Dehumidification of the room and recovery of lost calories
from washing machines and dryers.
Mini
200mm
Mini
100mm
670mm
mini
Ensure these minimum spaces indicated to avoid recirculating the air.
Leave a space of 500mm in front of the electrical equipment and 300mm in front of the hydraulic
equipment so that the water heater is accessible for its periodic servicing.
Installation
Use
Maintenance
Warranty
Interior/Interior
Mini
200mm
Mini
400mm
51
EN