The operating pressure of the heat exchanger circuit must not
exceed 0.3 MPa (3 bar) and its temperature must not exceed
100°C.
Before taking off the cover, make sure that the power is turned
off to prevent injury or electric shock.
The electrical installation must include an omnipolar cut-off
device (circuit-breaker, fuse) upstream of the appliance,
complying with local installation rules in force (30mA differential
circuit breaker). Grounding is mandatory. A special terminal
bearing a marker
In France, it is strictly forbidden to connect a product equipped
with a cable to a socket.
SERVICING - MAINTENANCE - TROUBLESHOOTING
Draining: Turn off the power supply and cold water, open the
hot water taps and then operate the drain valve of the safety
device. The pressure relief valve must be operated regularly to
remove scale deposits and to ensure that it is not blocked.
If the power cable is damaged, it must be replaced by the
manufacturer, their after sales service or a similarly qualified
person, in order to avoid any danger. These instructions are also
available from the customer service (contact details mentioned
on the appliance).
Maintenance by a qualified person:
a. Remove the scale sludge. Do not scrape or chip at lime scale
deposited on the casing because this may damage the lining.
b. Change the magnesium anode every 2 years or when its
diameter is less than 10 mm. Changing the shielded heating
element or the anode requires the water to be drained and the
seal changed.
WARNINGS
ELECTRICAL CONNECTION
is provided for this purpose.