Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Always allow to cool before cleaning.
WARNING: Do not allow any water to spill into the appliance when cleaning.
•
Use warm, soapy water and a damp cloth to clean the appliance.
•
Dry thoroughly after cleaning.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is
The unit is not switched on
not working
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Appliance does
Open end of bag not completely
not remove all
inserted
the air from the
Gaskets dirty
bag
Open end of bag is dirty
Bag may be punctured
Incorrect bags used
Suction nozzle blocked
Lid is not locked into position
correctly
Bags are not
Moisture in bag under the sealing
sealing correctly
bar
Incorrect bags used
End of bag not placed above sealing
bar
Technical Specifications
Note: Due to our continuous improvement process, the product specifications are subject to change
without notice.
Model
Voltage
CN515
220-240V~
50Hz
CN515_ML_A5_v7_20240902.indb 5
CN515_ML_A5_v7_20240902.indb 5
Probable Cause
Vacuum Pressure
Power
Current
(approx.)
110W
0.5A
Solution
Check the unit is plugged in correctly and
switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Open lid and reposition bag
Clean gaskets
Clean bag
Replace bag
Call Vacuum Pack machine supplier
Clear suction nozzle
Ensure lid is locked in position correctly
Ensure inside of the bag is dry and free from
moisture where it is to be sealed
Call Vacuum Pack machine supplier
Move end of bag over sealing bar
Dimensions
h x w x d mm
-0.75 Bar
87 x 357 x 148
EN
Weight
(kg)
1.4
5
2024/9/2 09:50
2024/9/2 09:50