3
PRELIMINARY OPERATIONS
3.1
Application limits
The following table shows the application limits of the various kits.
NIGHT ONE DAY
600 mm (*) ÷ 1100 mm
NIGHT ONE DAY
660 mm (*) ÷ 1300 mm
RADIO
NIGHT ONE DAY
660 mm (*) ÷ 1300 mm
AUTO
NIGHT ONE DAY
800 mm (*) ÷ 1300 mm
RADIO AUTO
3.2
Shutter functional check
First of all, check if the shutter is operating
correctly. If necessary, lubricate the hinges, and
then level the shutter. (Fig. 3.1)
3.3
Reference mark
Close the shutters, mark a line inside at 3 mm
from the closed shutter, on the lintel or on the sill
according to the selected type of installation.
This line will delimit the position of the frames.
(Fig. 3.2)
leaf
780 mm (*) ÷ 1400 mm
860 mm (*) ÷ 1400 mm
860 mm (*) ÷ 1600 mm
990 mm (*) ÷ 1600 mm
leaves
Fig. 3.2
(*) measure obtained
b y r e d u c i n g t h e
housing length
Fig. 3.1