Download Print deze pagina

Schluter Systems LIPROTEC LT EKE 24V15W Gebruikershandleiding pagina 28

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 49
Make sure that the power pack is not exposed to any strong vibrations or mechanical
loads at the place of installation.
Make sure that sufficient ventilation is provided.
Reversibly attach the power pack using suitable screws, washers and plugs. Use the
power pack's mounting straps.
6
Connection
Risk of fire due to overloaded connections!
Burning components and cables can lead to severe or deadly injuries.
Only ever connect one cable to a power pack's connection terminals.
Follow the special instructions in the directions for use if several components are to
be connected.
Possibility of electric shocks due to the power pack being connected incorrectly!
Electric shocks can lead to severe or deadly injuries.
Before carrying out any work, make sure that the power pack's mains plug is
unplugged.
Wait 10 seconds after unplugging the mains plug.
Close the housing cover on the power pack once work is complete.
Only plug the mains plug into the socket once all work is complete.
6.1 Connection variants
The components of the LIPROTEC system can be assembled and connected in the
following combinations:
One or more LED strips (LT ES 11 to LT ES 61), connected to a power pack with an
upstream light switch (see the "Directions for use for LED strips", Fig. F)
One or more LED strips (LT ES 11 to LT ES 61, LT ES 9), connected to a receiver for
remote control, with an upstream power pack and optional light switch (see the
"Directions for use for LED strips", Fig. E)
One or more LED strips (LT ES 11 to LT ES 61, LT ES 9), connected to a building
automation system that takes over the power supply and control functions (see the
"Directions for use for LED strips", Fig. G)
The possible connections applicable to the existing component are described below.
Directions for use for the power pack
DANGER
DANGER
EN
Connection
25

Advertenties

loading