EN
Transport and storage
Item number
Max. output current
Max. power
Min. power
Dimensions (L × W
× H) [mm]
4
Transport and storage
To transport and store components of the LIPROTEC system, proceed as follows:
Transport and store the components in the original packaging.
Store the components in a dry room.
Keep the components away from children.
5
Mounting
5.1 Optimizing radio noise suppression
Observe the following points for professional cable routing to obtain good radio noise
suppression and the greatest possible level of operating safety:
Mount the power packs at least 30 cm from the LED-conducting aluminium profiles.
While doing so, observe the minimum distances from neighbouring components (see
the "Directions for use for the power pack", Fig. C).
Properly lay the output lines at an appropriate distance from the earthed metal surfaces.
Make sure that the distance between receivers' or LED strips' mains cable and
connection cable is as large as possible (at least 5 cm) and that the mains and
connection cables are not laid in parallel.
This prevents interference between the mains cable and lamp connection cables.
Avoid crossing the mains cable and LED modules. If you cannot prevent crossing, for
safety reasons carry it out with the largest possible angle where technically possible.
This prevents HF interference on the mains cable.
5.2 Mount at installation point
Make sure that the scopes of protection according to DIN VDE 0100-701 are observed
when the components are used in bathrooms or wet rooms.
Make sure that the installation complies with the local requirements. Note the country-
specific deviations from the requirements set down in the LIPROTEC system
documentation.
24
LT EKE
24V100W
4.17 A
100 W
17 W
164 × 57 × 17
LT EKE
24V150W
6.25 A
150 W
25 W
177 × 57 × 18
Directions for use for the power pack
LT EKE
24V200W
8.33 A
200 W
33 W
195 x 67 x 31