Technical specifications
Radio frequency:
Receiver category:
Typ. open area RF range:
Duty cycle:
Max. switching capacity:
Life expectancy relay/
switching cycle:
Relay:
Switch type:
Operating mode:
Withstand voltage:
Protection class:
Method of operation:
Dimensions (W x H x D):
Weight:
Measuring range
Power
0 to 3680 W
Current
0 to 16 A
Voltage
200 to 255 V
Frequency
48.72 to 51.27 Hz
*Frequency range: 2 Hz to 2 kHz
Subject to technical changes.
40
868.3 MHz
SRD category 2
> 100 m
< 1 % per h
2300 W, 3680 W for 10 minutes
(ohmic load)
50000 (16 A, ohmic load)
Shutter contact
independently mounted switch
S1
2500 V
I
Type 1
59 x 123 x 40 mm (not incl. mains
plug)
166 g
Resolution
0.01 W
1 mA
0.1 V
0.01 Hz
Accuracy
1 %
± 0.03 W*
1 %
± 1 mA*
0.5 %
± 0.1 V
0.1 %
± 0.01 Hz