FLASHLIGHT FUNCTION

FAULT CODES (PRO 12 XL)

Reverse polarity
High current
Low voltage
- The voltage of one of the battery cells is between 1.1 V
and 2.4 V.
- The battery voltage is below 13.5 V.
Connect the charger and press the ON/OFF switch until
E0 disappears from the display. After this operation, the
charging of the product should be monitored.
* Products with S/N greater than "S2206...".

PROBLEM SOLVING (PRO 24 XL)

Troubleshooting
The screen is black and shows nothing.
Each connection causes a flashing red and
green "8" to appear on the display.
A fixed red "8" appears on the LCD screen
when the clamps are connected and an
alarm sounds.
A fixed red "8" appears on the LCD screen
as soon as the booster switches on. **
** Products with S/N less than "S2206..."
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
14
NOMAD POWER PRO 12 XL / 24 XL
Press the ON/OFF button on the LED (9) to activate the lighting.
Each new press changes the lighting mode (3 available modes: normal, strobe light,
SOS) until the light goes out.
Timed out
Low current
Causes
Sleep mode is on.
The booster doesn't detect a
battery.
The device detects a polarity
reversal.
Thermal protection of the booster.
Short circuit.
The battery is heavily discharged
(<4V).
High temperature
Short circuit
Over Voltage
Due to an imbalance in one of the battery cells, the voltage
of one of the cells is higher than 4.35 V. Stop charging and
contact your dealer.
Press the ON/OFF button or toggle the main
switch to the OFF then ON position. The screen
lights up again.
Turn on the lights or the radio so that the NOMAD
POWER detects a current load and activates.
Check the battery polarity. Red clamp to the
positive battery terminal (+) and the black clamp
to the negative (-).
The charger is overheated because the ambient
temperature is high. Wait a few minutes for the
booster to cool down before trying to start again.
Damaged battery. Change the battery.
Replace the vehicle battery.
EN
Low temperature
Unit is not
activating
Solutions