Download Inhoudsopgave Inhoud Print deze pagina

Settings; Setting A Fixed Temperature; Setting The Hot Water Stop; Troubleshooting - Stiebel Eltron WSN 10 Instructies Voor Gebruik En Installatie

Sensorkraan voor drukvaste gesloten
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

INsTALLATIoN

Settings

12. Settings
If required, you can set a fixed temperature and a hot water stop
at the sensor tap.

12.1 Setting a fixed temperature

You can set a fixed temperature at the sensor tap.
A
C
f Set the selected temperature as fixed by removing the lever
f
for adjusting the temperature and replacing it with a dummy
cap.

12.2 Setting the hot water stop

The hot water range can be locked by adjusting the Allen screw.
A
2,5
C
2,5
f Limit the setting range for hot water by turning the Allen
f
screw clockwise or anti-clockwise:
„+" = reduce the hot water setting range
„-" = increase the hot water setting range
www.stiebel-eltron.com 
B
2,5
B
2

13. Troubleshooting

Problem
Cause
Water does not run.
The "draw-off pause" is
activated.
The shut-off valve is
closed.
Water is running contin-
The solenoid valve is
uously.
faulty.
The tap switches inde-
The minimum supply
pendently.
pressure is too low.
The water flow is too low. The aerator is blocked.
The non-return valve is
faulty.
The strainer in the cold
water supply is blocked.
The tap is dripping.
The membrane is dirty. Clean/replace the sole-
The water does not have
The domestic hot water
the required temperature.
supply is faulty.
The tap does not respond
The touch area is faulty. Replace the PCB.
to touch.
The power supply unit
is faulty.
The power supply is in-
terrupted.
Short spray of water.
The battery is spent.

14. Maintenance

Cleaning the strainer
f If dirty, clean the strainer in the threaded cold water fitting.
f

15. Specification

15.1 Dimensions and connections

143
Ø54
103
Remedy
Deactivate the "draw-off
pause".
Open the shut-off valve.
Replace the solenoid
valve.
Check the supply line.
Clean/replace the aer-
ator.
Replace the non-return
valve.
Clean/replace the
strainer.
noid coil.
Check the domestic hot
water supply.
Replace the power sup-
ply unit.
Check the power supply.
Replace the battery.
Ø33,5
G3/8
WSN 10 | WSN 20  | 
21

Advertenties

Inhoudsopgave

Probleemoplossen

loading

Deze handleiding is ook geschikt voor:

Wsn 20

Inhoudsopgave