Download Inhoudsopgave Inhoud Print deze pagina

Cleaning, Care And Maintenance; Installation; Safety; General Safety Instructions - Stiebel Eltron WSN 10 Instructies Voor Gebruik En Installatie

Sensorkraan voor drukvaste gesloten
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

INsTALLATIoN

Cleaning, care and maintenance
6.

Cleaning, care and maintenance

f Never use abrasive or corrosive cleaning agents or abrasive
f
sponges.
f If the sensor tap is dirty or covered in limescale, clean it with
f
soapy water or diluted domestic vinegar, then rinse with
plenty of clean water. Dry the sensor tap with a cloth.
f For descaling, remove the aerator from the fitting. To avoid
f
inadvertently triggering the flow of water, activate a draw-off
pause; see chapter „Extended settings / Setting the draw-off
pause / Activating the draw-off pause".
www.stiebel-eltron.com 
INsTALLATIoN
7.

Safety

Only qualified contractors should carry out installation, commis-
sioning as well as maintenance and repair of the product.
7.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the product
are used.
DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
Damage to the appliance and environmental pollution
!
Drain the system when there is a risk of frost.
Note
To meet the required sound levels, install a pressure re-
ducing valve in the main line if the supply pressure is
more than 0.6 MPa.
7.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
Note
Water line pressures must be the same for domestic hot
water and cold water.
8.

Product description

The sensor tap is connected via two flexible pressure hoses with
dirt traps. A non-return valve has been fitted into the tap body.
8.1

Standard delivery

The following are delivered with the product:
- Power supply unit for WSN 10
- Battery for WSN 20, 1 x CR-P2 6 V (installed)
- 3 connection hoses
- 1 strainer
- 3 gaskets
- Fitting G3/8
WSN 10 | WSN 20  | 
19

Advertenties

Inhoudsopgave

Probleemoplossen

loading

Deze handleiding is ook geschikt voor:

Wsn 20

Inhoudsopgave