F 1 ~ F6 = RECOVERY HEART RATE LEVEL
u User press Test-key to start the H.R.C RECOVERY
u Get the result from F1 - F6.
1.0
1.0 < F < 1.9
2.0 < F < 2.9
3.0 < F < 3.9
4.0 < F < 5.9
6.0
Pulse Rate:
The whole set of heart rate detector include 2 sensors each side. Each
sensor has 2 pieces of metal parts. The correct way to detect is, to hold
gently both metal parts each hand. With the good signals picked up by the
computer, the heart symbol in the HEART RATE Display shall flash. Some-
times the heart rate value is not useable, based on wet hands or any other
contact problems during exercising. If you need high accuracy heart rate
value, you have to use an external heart rate measurement with a pulse
belt and pulse watch.
Cleaning, Checks and Storage of the Ergometer
bike:
1. Cleaning
Use only a less wet cloth for cleaning. Caution: Never use benzene,
thinner or other aggressive cleaning agents for surface cleaning as
this damage caused.
The device is only for private home use and for use suitable indoors.
Keep the unit clean and moisture from the device.
2. Storage
Plug out the power supply unit while intending the unit for more than
4 weeks not to use. Push the saddle slide toward the handlebar and
the seat support tube as deeply as possible into the frame. Choose
a dry storage in-house and put some spray oil to the pedal bearings
left and right, to the thread of the handlebar bolt, and on the thread
of the quick release for saddle support.
Cover the bike to protect it from being discolor by any sunlight and
dirty through dust.
3. Checks
We recommend every 50 hours to review the screw connections for
tightness, which were prepared in the assembly. Every 100 operating
hours, you should put some spray oil at the pedal bearings left and
right, to the thread of the handlebar bolt and to the thread of quick
release for saddle support.
Training area in mm
(for home trainer and user)
Outstanding
Excellent
Good
Fair
Below average
Poor
23
Exercising with App feature:
1. Download a desired APP depending on the operating system (APP
Store / Play Store) on your Smartphone/Tablet. (Note: The downloading of
apps maybe costs. Please observe the notes on any APP costs.)
2. Plug in the power for ergometer and place the smartphone/tablet di-
rectly to the tray of the computer to get a good connection continuously.
3. Activate the Bluetooth connection on your smartphone/tablet. (Should
this be already activated, deactivate the Bluetooth for short time and ac-
tivate new to terminate any remaining existing connections and thus to
obtain an interference-free Bluetooth connections. The smartphone/tablet
show you either immediately shortlist of available Bluetooth devices in your
environment or after open/launch the APP.
4. Select from the list the right devices and connect your smartphone/
tablet with the ergometer. On the backside of your ergometer computer is
a label with the Bluetooth device name, such as VISTA-BE - ??? ,
5. The ergometer computer beeps as soon as a Bluetooth connection is
done and displays the message „BT". If the Bluetooth connection is ter-
minated the computer beep again and the display switch to start screen.
Troubleshooting
If you cannot solve the problem with the following information,
please contact the authorized service center.
Problem
Possible Cause
Computer has
No power
no value at Dis-
adapter is well
play if you press
plugged or wall
any key.
power is without
power.
Computer is
Sensor impulse
not counting
missing base on
data and do not
not well plugged
switch on after
connection
start cycling.
Computer is
Sensor impulse
not counting
missing base on
data and do not
not correct posi-
switch on after
tion of sensor.
start cycling.
No pulse value
Pulse cable is
not plugged in.
No pulse value
Pulse sensors
not well connec-
ted
Free area in mm
(Training area and security area
(rotating 60cm))
Solution
Check that the power adapter
is properly plugged in, possibly
with another electric device
check if the wall power is fine.
Check the plug connections at
computer and inside of handle-
bar support.
Take off the cover and check
the distance between magnet
and Sensor. The magnet at
turning belt wheel should have
only less than < 5mm distance
against the sensor position.
Check the separately pulse
cable is well connected with
computer.
Screw out the screw for pulse
measurement and check if
plugs are well connected and no
damage at pulse cable.