2) limit sensor, for example, fl oor temperature sensor (sold as
accessory).
3) window contacts, card reader contacts or teleswitch contacts.
See Installer Advanced Programming Options for set-up instructions.
Models with remote sensor inputs
Terminal block for remote control/sensing
is located on the circuit board above the
battery compartment.
S1/D
S2/E
Confi gured for
remote room
sensor or limit
sensor

RX Receiver Wiring (RF models only)

RX1
ELECTRONICS
N L
1 2 3 4
COM
1) For mains voltage operated systems link terminal 2 to mains live supply.
2) Power supply to unit must not be switched by timeswitch.
S1/D
S2/E
Window or
teleswitch
contact
(NO or NC)
Confi gured for
window contact or
other contact such
as teleswitch
RX2 & RX3
A
ZONE
ZONE
1 ON
1 OFF
ELECTRONICS
B C 1 2 3 4 5 6
N
L
COM
ZONE
/D
/E
Remote
control
connections
S1/D
S2/E
Window
contact (NC)
Teleswitch
contact (NC)
Confi gured for
window contact
and other contact
such as teleswitch
TERMINAL 6
RX3 ONLY
ZONE
ZONE
ZONE
1 ON
1 OFF
2 ON
3 ON
GB
5