4-OPERATION
4-OPERATION
FEED SCREW ON
This function is useful to avoid alarm A01 caused by ignition failure due to an empty pellet tank, and can be activated with the stove off.
Once the pellet tank has been filled, enable the "START FEED SCREW" function. The loading system (feed screw) will fill up with pellets
in order to prevent the failed stove ignition alarm from triggering. As soon as the first pellets fall into the brazier, disable the function.
1.
Press key 1 (
) to access the settings menu
2.
Press key 4 (+) / 5 (-) to select the START FEED SCREW function
3.
Press key 6 (
) to confirm the START FEED SCREW function
4.
Press key 4 (+) / 5 (-) to select the function (ON/OFF)
5.
Press key 6 (
) to confirm
AIR RECIPE
This enables you to view and edit the air recipe settings. To access this function, you must enter password 1234.
This function enables you to adjust combustion air if the flame is too high or too low.
The available values are from -2 to +2.
1.
Press key 1 (
) to access the settings menu
2.
Press key 4 (+) / 5 (-) to select the AIR RECIPE function
3.
Press key 6 (
) to confirm the AIR RECIPE function
4.
Press key 4 (+) / 5 (-) to enter the first digit of the password
5.
Press key 9 (
)/10 (
6.
Press key 4 (+) / 5 (-) to enter the second digit of the password
7.
Repeat the above operation for the missing digits.
8.
Press key 6 (
) to confirm
To edit the AIR recipe, select one of the values available by pressing keys 4 (+) / 5 (-) and pressing key 6 (
The available values are:
-- 2 = - 10%
- 1 = - 5%
0 = (default value)
1 = + 5%
2 = + 10%
This function is used to adjust combustion air if the flame is insufficiently or excessively oxygenated.
Attention! All the adjustments must be performed solely by authorised and qualified personnel. Errors
or incorrect settings may cause hazardous situations and/or incorrect product operation. Any liability for
improper use of the product is entirely borne by the user and relieves the Manufacturer from any civil and
criminal liability.
PELLET RECIPE
This enables you to edit the pellet recipe settings. To access this function, you must enter password 1234.
This function is used to adapt the stove to the type of pellet in use. Since there are many types of pellets available on the market, operation
of the stove can vary according to the quality of the fuel.
The amount of pellets in the brazier can be increased or reduced:
• If the pellets tend to jam in the brazier due to an excess of fuel
• If the flame is increasingly higher even at low power values
• If the flame is always low
The available values are from -3 to +3.
The adaptive mode is available in this function. By activating the function (select ON), the stove adapts its operation in case of special
installations or when using poor quality pellets.
1.
Press key 1 (
) to access the settings menu
2.
Press key 4 (+) / 5 (-) to select the PELLET RECIPE function
3.
Press key 6 (
) to confirm the PELLET RECIPE function
Technical Dept. - All rights reserved - Reproduction is prohibited
Technical Dept. - All rights reserved - Reproduction is prohibited
) to select the next field
EN
EN
) to confirm.
57