Vita V
Key:
Protection remote access
NOTICE!
In order to execute a blocked function, first of all the valid password has to be entered. If the correct password is
entered then the desired function can be executed.
Interface
Keys:
,
,
,
,
COM1 / Baud / P / D / s
Key:
Start sign / End sign
Key:
Data memory
Key:
Port test
102
The password protection prevents the remote control of the printer.
,
,
COM1:
0 - serial interface Off
1 - serial interface On
2 - serial Interface On; no error message occurs in case of a transmission error.
Baud rate:
Indication of bits which are transferred per second.
Following values are possible: 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200.
P = Parity:
N - No parity
E - Even
O - Odd
Please observe that the settings correspond to those of the printer.
D = Data bits
Setting of data bits.
Value range: 7 or 8 Bits.
S = Stop bits
Indication of stop bits between bytes.
Value range: 1 or 2 stop bits.
SOH: Start of data transfer block
ETB: End of data transfer block
Standard: After starting a print order the printer buffer receives data as long as it is filled.
Advanced: During a current print order data is received and processed.
Off: After starting a print order no more data is received.
Check whether the data are transferred via the interface.
Press the
and
keys to select standard (on). Press the
port (COM1, USB, TCP/IP) is printed.
Hex format 01
Hex formal 17
English
key and the data sent via any