Elimination des éléments usés
Si l´appareil défectueux ne fonctionne plus ou ne peut être réparé, il
convient de procéder au rejet de l´appareil devenu inutilisable,
conformément aux prescriptions légales en vigueur.
Caractéristiques techniques
Alimentation électrique
Indicateur du courant
Température de service
Humidité relative de l'air
Désig-
Consom-
Volt
Ampère Réglage Ondulation Fusible
nation
mation
DC
DC
FSP 2/4
50 Watt
12V
2(4)A
FSP 3/5
120 Watt
24V
3(5)A
FSP 2/4
60 Watt
13,8V 2(4)A
FSP 4/6
100 Watt
13,8V 4(6)A
FSP 6
140 Watt
13,8V 6(8)A
FSP 8/10
180 Watt
13,8V 8(10)A
FSP 12/15 400 Watt
13,8V 12(15)A <15mV
FSP 20/22 450 Watt
13,8V 20(22)A <20mV
FSP 30/32 680 Watt
13,8V 30(32)A <30mV
Les valeurs de courant entre parenthèses désignent le prélèvement
de courant temporaire maximal pour maximum 5 minutes.
36
230V~(+/- 10%)/50Hz
Instrument à aiguille classe 5
de +10°C à +35°C
85% maximum, sans condensation
parfait
rest.
5x20 mm
10mV
<2.5mV
T0,8A/250V
<250mV <5mV
T0,8A/250V
10mV
<2.5mV
T0,8A/250V
10mV
<2.5mV
T0,8A/250V
<15mV
<2.5mV
T0,8A/250V
<15mV
<2.5mV
T1,0A/250V
<2.5mV
T1,6A/250V
<30mV
T2,5A/250V
<50mV
T4A/250V
The designation "transient" is defined with <5 minutes!
The indicator instrument supplies information about any output cur-
rent.
If exceeded or in case of a short, this will lead with each of the pow-
er units listed to overloading and thus to destruction.
The power unit is structured in compliance with protection class 1. It
is only approved for connection to shockproof sockets with protec-
tive grounding and an alternating current of 230V~ /50 Hz common-
ly used in households.
Any use in damp rooms or outdoors or under adverse ambient con-
ditions is not permitted. The following are adverse ambient condi-
tions:
- wetness or excessive humidity
- dust or combustible gases, vapours or solvents,
- strong vibrations
Use other than that described above will damage the product and
may involve other risks, such as shorts, fire or electric shock etc. Do
not modify or convert any part of the product. The safety instruc-
tions have to be observed at all times!
17