GROUP S.P.A.
CONFIGURATION OF THE DEVICES
Programming telephone Art. 2408W/A, 2410W, 2428W and bracket Art. 4714W/2
• Each telephone or bracket in the system is identified
by means of its own code. This code must be set by means
of the Dip switches on the telephone card or on the bracket
(see figures).
Programming switching device Art. 1224
• Example of coding switching device Art. 1224 of staircase A
minimum number: 1, maximum number: 10.
N
M I
6
5
4
3
2
1
O
N
• Each switching device module is fitted with a pair of Dip
switches with 8 selectors (see figure). The two Dip switches
define the minimum and maximum range - MIN - MAX - of
codes which can be recognised by the switching device.
40
MT SB2 01
All manuals and user guides at all-guides.com
X
M A
8
7
6
5
4
3
2
1
O
8
N
7
STAIRCASE A
• The user code must be set according to the corresponding one
described in the programming table on page 41.
• Coding can take place at any time, even without a power
supply.
4700 W
4700 W/I
4701 W/A
4700 W
4700 W/I
4701 W/A
SCALA A
N° 1÷10.
N° 1÷10
• Remember that the MIN and MAX Dip switches define the lowest and
highest user codes respectively which can be connected to the riser.
• For setting the values desired, refer to the table on page 41.
• Distinct switching devices must manage code ranges which are
not overlapping.
4700 W
4700 W/I
4701 W/A
4700 W
4700 W/I
4701 W/A
STAIRCASE B
SCALA B
N° 11÷20.
N° 11÷20
MAIN ENTRANCE FROM N° 1÷20.
PORTA PRINCIPALE DAL N° 1÷20.