TROUBLESHOOTING
Troubles
Possible Causes
The unit
•
Water full indicator lamp
does not
blinks and water tank is full.
start when
•
Room temperature is higher
pressing
than the setting temperature.
power
(Electric heating mode)
button.
•
Room temperature is lower
that the setting temperature.
(Cooling mode)
The unit
•
The doors or windows are not
doesn't cool
closed.
enough.
•
There are heat sources inside
the room.
•
Hot air exhaust hose is not
connected or blocked.
•
Temperature setting is too
high.
•
Air inlet in blocked.
Auto Power-
•
Heating protection, when the
Off in heating
temperature at the air outlet
mode.
exceeds 70 degrees, the unit
will power off automatically.
Noisy.
•
The ground is not level or not
flat enough.
•
The sound comes from the
flowing of the refrigerant
inside the air conditioner.
E0 Code.
•
Room temperature sensor
failed.
E2 Code.
•
Water tank full
All manuals and user guides at all-guides.com
Suggested Remedies
•
Drain the water out of the water
tank.
•
Adjust the temperature.
•
Make sure all the windows and
doors are closed.
•
Remove the heat sources if
possible.
•
Connect or clean the hot air
exhaust hose.
•
Reset the temperature.
•
Clean the air inlet.
•
Allow room temperature to cool
before re-starting the unit.
•
Place unit on a flat, level ground if
possible.
•
Replace room temperature
sensor.
•
Please empty the water tank.
THE PRODUCT OR EQUIPMENT CONTAINS
FLUORINATED GREENHOUSE GAS.
Art.nr.
Coolant:
Quantity in kg:
Global Warming Potential:
Art.nr.
Coolant:
Quantity in kg:
Global Warming Potential:
Art.nr.
Coolant:
Quantity in kg:
Global Warming Potential:
Art.nr.
Coolant:
Quantity in kg:
Global Warming Potential:
Instruction manual
352005
R290
0,10
3
352007
R290
0,14
3
352009
R290
0,16
3
352010
R290
0,16
3
EN