ALARM EVENT DATA SET FUNCTION:
If
an
alarm
is
triggered,
automatically creates a special Alarm Event data
set.
Like a normal data record, this data record
contains a snapshot of the temperature and
humidity values as well as the current time and
date.
Also the value that triggered the alarm is marked in
this Alarm Event data set.
The Alarm Event data sets are recorded in addition
to the normal data sets and are automatically listed
in the history of normal data sets.
Note:
The Alarm Event data records can be displayed in the history
mode on the instrument separately.
HISTORY MODE:
You also have the option to read the data sets and the Alarm
Event data sets on the instrument itself.
Press HIST button in normal mode.
HIST appears in the display.
The memory indication is hidden.
The values of the latest data set as well as the time
and date when this data set was recorded will be
shown.
Use the button as follows to navigate in history mode:
„HIST " --------------------next / older record
„OK/MAX/MIN" -------- -previous / recent record
„ALM" ----------------------separation of the Alarm Event-
data sets
„SET" --------------------- Back to normal mode